Protocol Converter

  • ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll tabi Ilana ti kii ṣe boṣewa si Oluyipada ProfiNet

    ODOT-PNM02 V2.0 / V2.1: Modbus-RTU/ASCll tabi Ilana ti kii ṣe boṣewa si Oluyipada ProfiNet

    ODOT-PNM02 V2.1

    Modbus (titunto si / ẹrú, RTU / ASCII) si ProfiNET, 2 ibudo ni tẹlentẹle ibudo (RS485/ RS232 / RS422), atilẹyin 50 iho , 200 ofin ni TIA portal (nipasẹ software tunto), atilẹyin MAX 60 ẹrú

    ♦ Ṣe atilẹyin iyipada ilana laarin Modbus ati PROFINET

    ♦ Ṣe atilẹyin 2 * RS485/RS232 tabi 1 * RS422

    ♦ Atilẹyin Modbus titunto si tabi ẹrú, ati atilẹyin RTU tabi ASCII

    ♦ Ṣe atilẹyin iwọn otutu iṣẹ ti -40 ~ 85°C

    ♦ Ṣe atilẹyin agbegbe data: 2 tẹlentẹle Modbus-RTU/ASCII si ẹnu-ọna PROFIBUS pẹlu Max.igbewọle 1440 bytesand Max.o wu 1440 baiti

    ♦ Ṣe atilẹyin atunto bọtini kan

    ODOT-PNM02 V2.0 ṣe atilẹyin awọn iho ti o pọju: 50

    ODOT-PNM02 V2.1 ṣe atilẹyin awọn ẹrú 60 (awọn aṣẹ kika ati kikọ 200)

  • ODOT-S1E1 V2.0: Tẹlentẹle Gateway

    ODOT-S1E1 V2.0: Tẹlentẹle Gateway

    Eleyi jẹ a converter ni idagbasoke nipasẹ Sichuan Odot Automation System Co., LTD laarin RS232/485/422 ati TCP/UDP.This bèèrè converter le awọn iṣọrọ so ni tẹlentẹle ibudo awọn ẹrọ to àjọlò ati ki o mọ nẹtiwọki igbesoke ti ni tẹlentẹle ibudo awọn ẹrọ.

    Oluyipada Ilana ṣe atilẹyin iṣẹ “gbigba data”, eyiti o le ṣeto bi alabara tabi olupin.Iṣẹ yii le ni irọrun mọ ibaraẹnisọrọ data laarin PLC, olupin ati awọn ẹrọ Ethernet miiran ati awọn ẹrọ ibudo ni tẹlentẹle ti o wa labẹ.

    Ṣe atilẹyin olupin TCP ati TCP alabara gbigbe sihin
    Atilẹyin UDP sihin gbigbe ati foju ni tẹlentẹle ebute oko
    Ṣe atilẹyin gbigbe sihin pẹlu tabi laisi ilana.Ilana gbigbe sihin ṣe atilẹyin MODBUS RTU/ASCII
    Ṣe atilẹyin awọn aye atunto ẹrọ aṣawakiri WEB (Awọn paramita ti o wọpọ) Oṣuwọn baud ibudo ni tẹlentẹle 1200 si 115200 bps

  • MG-CANEX le ṣii si Modbus TCP oluyipada

    MG-CANEX le ṣii si Modbus TCP oluyipada

    MG-CANEX Protocol Converter

    CAN ṣii si oluyipada Ilana Modbus TCP

    MG-CANEX jẹ oluyipada ilana lati CANopen si Modbus TCP.Ẹrọ naa n ṣiṣẹ bi oluwa ni nẹtiwọọki CANopen ati pe o le sopọ si awọn ẹrọ CANopen ti o ṣe deede.Gbigbe data n ṣe atilẹyin PDO, SDO, ati iṣakoso aṣiṣe ṣe atilẹyin Heartbeat.O ṣe atilẹyin amuṣiṣẹpọ ati fifiranṣẹ ifiranṣẹ asynchronous.

    Gẹgẹbi olupin TCP ni nẹtiwọọki Modbus TCP, ẹrọ naa le wọle si nipasẹ awọn alabara TCP 5 ni akoko kanna, ati pe o le sopọ si oludari PLC ati ọpọlọpọ iru sọfitiwia iṣeto ni.O tun le sopọ transceiver opiti ati lati mọ gbigbe data jijin-gun.

  • ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Ni wiwo si EtherNet

    ODOT-S7MPIV2.0: PPI/MPI/PROFIBUS Ni wiwo si EtherNet

    ♦ Fi sori ẹrọ lori ibudo ibaraẹnisọrọ PPI/MPI/PROFIBUS ti PLC, ni gbogbogbo laisi ipese agbara ita

    ♦ Ṣe atilẹyin awọn awakọ ibaraẹnisọrọ Siemens S7 Ethernet, pẹlu MicroWIN, STEP7, TIA Portal, WinCC ati bẹbẹ lọ.

    ♦ Ijọpọ pẹlu olupin Modbus-TCP, agbegbe data Modbus le jẹ laifọwọyi tabi ṣatunkọ si maapu lati forukọsilẹ S7-200/300/400

    ♦ S7TCP asopọ ati ki o Modbus-TCP ibaraẹnisọrọ le ti wa ni mo daju ni nigbakannaa

    ♦ Titi di awọn asopọ kọnputa agbalejo 32 ni atilẹyin

    ♦ MPI si S7 Ethernet/Modbus-TCP oluyipada

    ♦ Atilẹyin Ọkan-Kọtini atunto

  • ODOT-DPM01: Modbus-RTU to Profibus-DP Converter

    ODOT-DPM01: Modbus-RTU to Profibus-DP Converter

    ♦ Ṣe atilẹyin iyipada ilana laarin Modbus ati PROFIBUS

    ♦ Ṣe atilẹyin RS485, RS422 ati Rs232

    ♦ Atilẹyin Modbus oluwa ati ẹrú, ati atilẹyin RTU tabi ASCII

    ♦ Ṣe atilẹyin agbegbe iṣẹ ti -40 ~ 85 ° C

    ♦ PROFIBUS-DP: Max.Input 244 baiti, Max.O wu 244 baiti

    ♦ DPM01: 1-ọna Modbus to PROFIBUS ẹrú ẹnu-ọna, apao ti igbewọle ati awọn ti o wu ni 288 baiti.

    ♦ DPM02: (isọdi) 1-ọna Modbus-RTU to PROFIBUS ẹrú ẹnu, apao ti igbewọle ati outputis488 baiti.

  • ODOT-S2E2: 2 Modbus Serial RTU/ASCII si Modbus TCP Converter

    ODOT-S2E2: 2 Modbus Serial RTU/ASCII si Modbus TCP Converter

    ♦ Ṣe atilẹyin iyipada ilana laarin Modbus-RTU ati Modbus-TCP

    ♦ Ṣe atilẹyin asopọ ti awọn alabara TCP5 ni nigbakannaa

    ♦ ODOT-S2E2 ṣe atilẹyin 2 * RS485

    ODOT-S4E2 ṣe atilẹyin onirin ti RS485/RS232/RS422

    ♦ Kọọkan ni tẹlentẹle ibudo atilẹyin Modbus masterand ẹrú

    ODOT-S2E2: 2 tẹlentẹle Modbus-RTU/ASCII si Modbus-TCP Server ẹnu-ọna

    ODOT-S4E2: 4 ni tẹlentẹle Modbus-RTU/ASCII si Modbus-TCP Server ẹnu-ọna

    ♦ Ṣe atilẹyin atunto bọtini kan

    ♦ Ipo iṣẹ-ọna ẹnu-ọna: Gbigbe sihin, maapu adirẹsi

  • ODOT-S4E2: 4 Tẹlentẹle Modbus RTU/ASCII si Modbus TCP oluyipada

    ODOT-S4E2: 4 Tẹlentẹle Modbus RTU/ASCII si Modbus TCP oluyipada

    ♦ Ṣe atilẹyin iyipada ilana laarin Modbus-RTU ati Modbus-TCP

    ♦ Ṣe atilẹyin asopọ ti awọn alabara TCP5 ni nigbakannaa

    ♦ ODOT-S2E2 ṣe atilẹyin 2 * RS485

    ODOT-S4E2 ṣe atilẹyin onirin ti RS485/RS232/RS422

    ♦ Kọọkan ni tẹlentẹle ibudo atilẹyin Modbus masterand ẹrú

    ODOT-S2E2: 2 tẹlentẹle Modbus-RTU/ASCII si Modbus-TCP Server ẹnu-ọna

    ODOT-S4E2: 4 ni tẹlentẹle Modbus-RTU/ASCII si Modbus-TCP Server ẹnu-ọna

    ♦ Ṣe atilẹyin atunto bọtini kan

    ♦ Ipo iṣẹ-ọna ẹnu-ọna: Gbigbe sihin, maapu adirẹsi